Control Pressure kpa (kgf/cm², psi) |
0 ~ 539.37 (0 ~ 5.5, 0 ~ 78.23) |
Current value(mA) |
0 ~ 850 |
Internal resistance(Ω) |
5.1 ± 0.3 |
Output Speed Sensor Description
The output speed sensor (A) is a vital unit that measures the rate of
rotation of the transaxle's turbine shaft and output shaft, and delivers the
readings to the Transaxle Control Module ...
Service Standard
Item
Specification
Ignition Timing (°)
BTDC 6 ± 10
Idle Speed (rpm)
A/C OFF
Neutral, N, P-range
680 ± 100
D-range
...
Closing the tailgate
To close the tailgate, lower and push down the tailgate firmly. Make sure that
the tailgate is securely latched.
WARNING
Make sure your hands, feet and other parts of your body are safely out of
...