1. |
Disconnect the negative (-) battery terminal.
|
2. |
Remove the LDWS unit cover (A).
|
3. |
Remove the LDWS unit connector (A).
|
4. |
Remove the LDWS unit (A) after widening the mounting clips.
|
Filler-Neck Assembly Installation
1.
Install in the reverse order of removal.
Filler-neck assembly bracket
installation nut :
3.9 ~ 5.9 N.m (0.4 ~ 0.6 kgf.m, 2.9 ~ ...
Circuit Diagram
...
Input Speed Sensor Specifications
▷ Type: Hall effect sensor
Operation condition (°C)°F
((-)40 ~ 150)) -40 ~ 302
Air gap(mm)in.
(0.95 ~ 1.55) 0.950 ~ 1.55
Output voltage ...