1. |
Turn the ignition switch OFF and disconnect the battery negative
(-) cable.
|
2. |
Disconnect the CVVT oil control valve connector (A).
|
3. |
Remove the installation bolt (B), and then remove the valve from
the engine.
[Bank 1 / Intake]
[Bank 1 / Exhaust]
|
Oil Pump Description
The oil pump is built-in as a single unit with the 26Brake chamber. Rotation
of the pump builds the hydraulic pressure needed for the lubrication of the
various parts of the transaxle and ope ...
Rear Glass Defogger Switch Installation
1.
Install the heater control unit.
2.
Install the center fascia panel.
...
Inspection
Throttle Position Sensor (TPS)
1.
Connect the GDS on the Data Link Connector (DLC).
2.
Start the engine and measure the output voltage of TP ...