Kia Sorento: Specifications - Automatic Transaxle System - Kia Sorento XM 2011-2024 Service ManualKia Sorento: Specifications

Second Generation XM (2011-2024) / Kia Sorento XM 2011-2024 Service Manual / Automatic Transaxle System / Specifications

Item
Specifications
Transaxle  type
A6LF2
Engine model
Gasoline  3.3 GDI
Torque converter type
3-element, 1-stage, 2-phase type
Torque converter size
Ø260 mm (10.2362 in.)
Oil pump system
Parachoid
Friction elements
Clutch: 2EA
Brake: 3EA
OWC : 1EA
Planetary gear
 3EA
Gear ration
1st
4.651
2nd
2.831
3rd
1.842
4th
1.386
5th
1.000
6th
0.772
Reverse
3.393
Final gear ratio
3.041
Fluid pressure balance piston
2EA
Accumulator
4EA
Solenoid valve
8EA (VFS:6EA, ON/OFF:2EA)
Shift lever position
 4 Range (P,R,N,D)
Oil filter
 1EA

VFS: Variable Force Solenoid
Sensors
Input Speed Sensor
▷ Type: Hall effect sensor
▷ Specifications
Operation condition (°C)°F
((-)40 ~ 150)) -40 ~ 302
Air gap(mm)in.
(0.95 ~ 1.55) 0.950 ~ 1.55
Output voltage(V)
High
1.18 ~ 1.68
Low
0.59 ~ 0.84

Output Speed Sensor
▷ Type: Hall effect sensor
▷ Specifications
Operation condition (°C)°F
((-)40 ~ 150)) -40 ~ 302
Air gap(mm)in.
(1.45~1.9) 0.0571~0.0748
Output voltage (V)
High
1.18 ~ 1.68
Low
0.59 ~ 0.84

Oil Temperature Sensor
▷ Type: Negative thermal coefficient type
▷ Specifications
Temp.(°C)°F
Resistance (kΩ)
(-40)-40
48.1
(-20)-4.0
15.6
(0)32.0
5.88
(20)68.0
2.51
(40)104.0
1.11
(60)140.0
0.61
(80)176.0
0.32
(100)212.0
0.18
(120)248.0
0.10
(140)284.0
0.06
(165)329.0
0.03

Inhibiter Switch
▷ Type: Combination of output signals from 4 terminals
▷ Specifications
Power supply (V)
12
Output type
Pin to Pin

Solenoid Valves
Direct control VFS[26/B, T/CON]
▷ Control type : Normal low type
Control Pressure kpa
(kgf/cm², psi)
0 ~ 539.37 (0 ~ 5.5, 0 ~ 78.23)
Current value(mA)
0 ~ 850
Internal resistance(Ω)
5.1 ± 0.3

Direct control VFS[UD/B, OD/C, 35R/C]
▷ Control Type : Normal high type
Control Pressure kpa
(kgf/cm², psi)
539.370 ~ 0 ( 5.5 ~ 0, 78.23 ~ 0)
Current value(mA)
0 ~ 850
Internal resistance(Ω)
5.1 ± 0.3

Line Pressure Control VFS
▷ Control type : Normal high type
Control Pressure kpa
(kgf/cm², psi)
539.370 ~ 0 ( 5.5 ~ 0, 78.23 ~ 0)
Current value(mA)
0 ~ 850
Internal resistance(Ω)
5.1 ± 0.3

ON/OFF Solenoid Valve(SS-A, SS-B)
▷ Control type : Normal low type
Control pressure kpa
(kgf/cm², psi)
490.33 (5.0, 71.12)
Internal resistance(Ω)
10 ~ 11

Solenoid Valve Operation Table

SS-A
SS-B
UD/B-VFS
OD/C-VFS
35R/C-VFS
26/B-VFS
N/H
N/H
N/H
N/L
N, P






1
Δ


Δ


2






3






4






5






6






L






R







● : Connected status
Δ : Connedted at vehicle speed above 8km/h
Tightening Torques
Item
 N.m
 Kgf.m
 lb-ft
TCM mounting bolt/nut
9.8 ~ 11.8
1.0 ~ 1.2
7.2 ~ 8.7
Shift cable bracket mounting bolt
14.7 ~ 21.6
1.5 ~ 2.2
10.9 ~ 15.9
Input shaft speed sensor mounting bolt
9.8 ~ 11.8
1.0 ~ 1.2
7.2 ~ 8.7
Output shaft speed sensor mounting bolt
9.8 ~ 11.8
1.0 ~ 1.2
7.2 ~ 8.7
Shift lever assembly bolt
8.8 ~ 13.7
0.9 ~ 1.4
9.4 ~ 10.8
Inhibitor switch mounting bolt
9.8 ~ 11.8
1.0 ~ 1.2
7.2 ~ 8.7
Manual control lever
17.6 ~ 24.5
1.8 ~ 2.5
13.0 ~ 18.1
Valve body mounting bolt
9.8 ~ 11.8
1.0 ~ 1.2
7.2 ~ 8.7
Valve body cover mounting bolt
13.7 ~ 15.7
1.4 ~ 1.6
10.1 ~ 11.6
ATF Warmer mounting bolt
7.8 ~ 11.8
0.8 ~ 1.2
5.8 ~ 8.7
Oil drain plug
38.2 ~ 48.1
3.9 ~ 4.9
28.2 ~ 35.4
Torque converter mounting bolt
45.1 ~ 52.0
4.6 ~ 5.3
33.3 ~ 38.3
Starter motor mounting bolts
49.0 ~ 63.7
5.0 ~ 6.5
36.2 ~ 47.0
Automatic transaxle upper mounting bolt (TM=>Eng)
42.2 ~ 53.9
4.3 ~ 5.5
31.1 ~ 39.8
49.0 ~ 63.7
5.0 ~ 6.5
36.2 ~ 47.0
Automatic transaxle upper mounting bolt (Eng=>TM)
78.5 ~ 98.1
8.0 ~ 10.0
57.9 ~ 72.3
39.2 ~ 46.1
4.0 ~ 4.7
28.9 ~ 34.0
Automatic transaxle support bracket bolt
58.8 ~ 78.5
6.0 ~ 8.0
43.4 ~ 57.9
Automatic transaxle mounting bracket bolt
88.3 ~ 107.9
9.0 ~ 11.0
65.1 ~ 79.6

Automatic Transaxle System
...

Lubricants
Item Specified lubricant Quantity Transaxle fluid ATF SP-Ⅳ or equivalent 7.8 L (2.06 U.S gal.,8.24 U.S.qt., 6.86 Imp.qt.) ...

See also:

Cooling Fan Description
Control the cooling motor voltage in according to the duty(300Hz) of ECM. [ECU → PWM Input Signal(SI : 300Hz)] Signal Input Duty (%) Motor Voltage (V) 10 ...

Start/Stop Button Inspection
1. It will be able to diagnose defects of Smart key with GDS quickly. GDS can operates actuator forcefully, input/output value monitoring and self diagnosis. ...

Heater Unit Components
1. Heater Case 2. B Pillar Case 3. Shower Duct 4. PTC Heater 5. Heater Core 6. Heater Core Cover 7. Mode Actuator 8. Mode Bracket 9. Mode Lever Main 10. Def D ...

Copyright © www.ksmanual.com 2014-2024