1. |
Turn the ignition switch OFF.
|
2. |
Disconnect the CCV connector.
|
3. |
Measure resistance between the CCV terminal 1 and 2.
|
4. |
Check that the resistance is within the specification.
|
5. |
Disconnect the vapor hose connected with the canister from the
CCV.
|
6. |
Connect a vacuum pump to the nipple.
|
7. |
Ground the CCV control line and apply battery voltage to the CCV
power supply line.
|
8. |
Apply vacuum and check the valve operation.
|
Specifications
Direct control VFS[LINE Pressure]
▷ Control type : Normal high type
Control Pressure kpa
(kgf/cm², psi)
539.370 ~ 0 ( 5.5 ~ 0, 78.23 ~ 0)
Current va ...
Front Bumper Replacement
•
Pry the trim off using a plastic trim tool and apply protective
tape around the rela ...
Relay Box (Engine Compartment) Inspection
1.
Disconnect the negative (-) battery terminal.
2.
Pull out the relay from the engine compartment relay box.
Power Relay (Type A)
...