1. |
Turn the ignition switch OFF and disconnect the battery negative
(-) cable.
|
2. |
Disconnect the engine coolant temperature sensor connector (A).
|
3. |
Remove the spring clip (A), and then pull the sensor from the
water temperature control assembly.
|
Wave Form
...
Inspection
1.
Connect the GDS on the Data Link Connector (DLC).
2.
Turn the ignition switch ON.
3.
Measure the output volt ...
Purge Control Solenoid Valve (PCSV)
Purge Control Solenoid Valve (PCSV) is installed on the surge tank and
controls the passage between the canister and the intake manifold. It is a solenoid