Item |
Specification |
|
Rated voltage |
13.5V, 130A |
|
Speed in use |
1,000 ~ 18,000 rpm |
|
Voltage regulator |
IC Regulator built-in type |
|
Regulator Setting Voltage |
External mode |
Refer to below graph |
Internal mode |
14.55 ± 0.3V |
|
Temperature Gradient |
External mode |
0 ± 3 mV / °C |
Internal mode |
-3.5 ± 2mV / °C |
Spark Plug Installation
1.
Install in the reverse order of removal.
Tightening torque:
14.7 ~ 24.5 N.m (1.5 ~ 2.5 kgf.m, 10.8 ~ 18.0 Ib-ft)
...
ECM Problem Inspection Procedure
1.
TEST ECM GROUND CIRCUIT: Measure resistance between ECM and chassis
ground using the backside of ECM harness connector as ECM side check
point. If the problem is fo ...
Cylinder Head Removal
•
Use fender covers to avoid damaging painted surfaces.
•
...