[Rotor] |
1. |
Check that there is continuity between the slip rings (C).
|
2. |
Check that there is no continuity between the slip rings and the
rotor (B) or rotor shaft (A).
|
3. |
If the rotor fails either continuity check, replace the alternator.
|
[Stator] |
1. |
Check that there is continuity between each pair of leads (A).
|
2. |
Check that there is no continuity between each lead and the coil
core.
|
3. |
If the coil fails either continuity check, replace the alternator.
|
Control System Composition
...
Auto Defogging Sensor Description
The auto defogging sensor is installed on the front window glass. The
sensor judges and sends signal if moisture occurs to blow out wind for defogging.
The air conditioner control module rece ...
IMS Control Switch Inspection
1.
Disconnect the IMS control switch connector.
2.
With the power IMS control switch in each position, make sure
that continuity ex ...