Purge Control Solenoid Valve (PCSV)
Purge Control Solenoid Valve (PCSV) is installed on the surge tank and
controls the passage between the canister and the intake manifold. It is a solenoid
valve and is open when the ECM groun ...
Specifications
Direct control VFS[OD/C]
▷ Control type : Normal high type
Control Pressure kpa
(kgf/cm², psi)
539.370 ~ 0 ( 5.5 ~ 0, 78.23 ~ 0)
Current value(mA)
...
TPMS Sensor Description
1.
Mode
(1)
Configuration State
A.
All sensors should be in the Low Line state.
...