1. |
Disconnect the negative (-) battery terminal.
|
2. |
Pull out the relay from the engine compartment relay box.
|
1. |
There should be continuity between the No.30 and No.87 terminals
when power and ground are connected to the No.85 and No.86 terminals.
|
2. |
There should be no continuity between the No.30 and No.87 terminals
when power is disconnected.
|
1. |
There should be continuity between the No.30 and No.87 terminals
when power and ground are connected to the No.85 and No.86 terminals.
|
2. |
There should be continuity between the No.30 and No.87a terminals
when power is disconnected.
|
3. |
There should be no continuity between the No.30 and No.87 termianls
when power is disconnected.
|
1. |
There should be continuity between the No.30 and No.87 terminals
when power and ground are connected to the No.85 and No.86 terminals.
|
2. |
There should be no continuity between the No.30 and No.87 terminals
when power is disconnected.
|
1. |
Be sure there is no play in the fuse holders, and that the fuses
are held securely.
|
2. |
Are the fuse capacities for each circuit correct?
|
3. |
Are there any blown fuses?
If a fuse is to be replaced, be sure to use a new fuse of the
same capacity. Always determine why the fuse blew first and completely
eliminate the problem before installing a new fuse.
|
|
1. |
Disconnect the negative(-) battery terminal.
|
2. |
Push 3 hooks in the engine room relay box out to the arrow direction
and put up the EMS box assembly (A).
|
3. |
Disconnect the connector and remove the EMS box assembly (A).
|
Alternator Specification
Alternator
Item
Specification
Rated voltage
13.5V, 130A
Speed in use
1,000 ~ 18,000 rpm
Voltage regulator
IC Regulator bui ...
Heater Unit Components
1. Heater Case
2. B Pillar Case
3. Shower Duct
4. PTC Heater
5. Heater Core
6. Heater Core Cover
7. Mode Actuator
8. Mode Bracket
9. Mode Lever Main
10. Def D ...
Lubricants
Items
Lubricants
Quantity (g)
Front driveshaft
LSJ 104
SH06-VX21
240 ~ 255
UBJ 104
RBA
165 ~ 175
LSJ 100
...