1. |
There should be continuity between the No.1 and No.3 terminals
when power and ground are connected to the No.2 and No.10 in the ICM-A.
|
1. |
There should be continuity between the No.16 and No.15 terminals
when power and ground are connected to the No.13 and No.14 in the ICM-A.
|
1. |
There should be continuity between the No.8 and No.20 terminals
when power and ground are connected to the No.13 and No.12 in the ICM-A.
|
1. |
There should be continuity between the No.19 and No.7 terminals
when power and ground are connected to the No.13 and No.11 in the ICM-B.
|
1. |
There should be continuity between the No.12 and No.22 terminals
when power and ground are connected to the No.21 and No.22 in the ICM-B.
|
1. |
There should be continuity between the No.17 and No.4 terminals
int the ICM-A when power and ground are connected to the No.2 and No.1
in the ICM-B.
|
1. |
There should be continuity between the No.20 and No.16 terminals
when power and ground are connected to the No.17 and No.6 in the ICM-B.
|
1. |
There should be continuity between the No.15 and No.13 terminals
when power and ground are connected to the No.5 and No.9 in the ICM-B.
|
1. |
There should be continuity between the No.6 and No.18 terminals
in the ICM-A when power and ground are connected to the No.4 and No.3
in the ICM-B.
|
Installation
1.
Install the key lock cylinder.
2.
Install the illumination bulb, lens and cover.
3.
Install the key warning ...
Catalytic Converter Installation
1.
Install in the reverse order of removal.
...
Compression Pressure Inspection
If the there is lack of power, excessive oil consumption or poor fuel
economy, measure the compression pressure.
...